Shandong Isentrol Electronic Technology Co., Ltd

SR618C6 Solar Controllers Solar Water Heater Controllers Solar Smart Controllers

 

SR618C6 Solar Controllers Solar Water Heater Controllers Solar Smart Controllers

Picture SR618C6-solar-water-heater-controllers 
Model  SR618C6
Suitable for  Split solar water heater
Working Principle  
Technical Data  1.Appearance  of  controller:  see  product  itself  (  dimension:  210mm  x145mm  x48mm)
2.Power  supply:AC230V  ±10%      
3.Power  consumption:< 3W 
4.Accuracy of temperature measuring: ± 2oC
5.Range of collector temperature measuring: -10 ~200 oC
6.Range of tank temperature measuring: 0 -100 oC
7.Suitable power of pump: 4 pumps possible to be connected, power of each pump ≤ 600W. 
8.Suitable power of auxiliary heating:power ≤1500W
9.Inputs: 6 sensors, 
           2 piece Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
           4 pieces NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC), 
10.Ambient temperature :-10oC - 50oC. 
11.Water proof grade:IP40.

 

Voltage 220V,110V is availabe against request, 24V is available for 50 sets above order.
Main Function

1.SYSTME(SYS1~SYS12)
2.DT  O  &  DT  F    Temperature  difference  controlling  the  Solar  circuit  pump
3.THET  Timing  heating
4.EM  Emergency  collector  temperature(emergency  switch-off  temperature  of  collector)
5.CMX  Maximum  limited  collector  temperature(collector  cooling  function)
6.CMN  low  temperature  protection  of  collector
7.CFR  frost  protection  of  collector
8.SMX  Maximum  temperature  of  tank
9.REC  Tank  re-cooling  function
10.MAX1  Maximum  turnoff  temperature  (for  solid  fuel  boiler,  return  heating,  heat  transferring    between  tanks)
11.MIN1  Minimum  turn-on  temperature  (for  solid  fuel  boiler,  return  heating,  heating  transferring  between  tanks)
12.DVWG  Anti-Legionella  function
13.CIRC  Temperature  controlled  hot  water  circulation  pump
14.nMIN  Solar  circulation  pump  speed  adjusting(RPM  speed  controlling)
15.OHQM  Thermal  energy  measuring
16.Priority  logic  of  tank
17.INTV  Pump  interval  fucntion
18.BYPR  High  temperature  by-pass  function(Tank  temperature  automatically  adjusting)
19.Holiday  fucntion
20.HND  Manual  mode
21.PASS  Password  setting
22.RSET  Recovery  to  factory  setting
23.Manual  Heating
24.Temperature  query  function
25.Memory  Protection
26.Anti-dry  heating  protection
27.Screen  protection
28.Trouble  protection

System Diagram SR618C6-solar-water-heater-controller-systems 
Packing List

 

Controller……………………………………………………………………1
Operation manual.............................................................................1
PT1000 sensor (size: dia.6*50mm, cable length1.5m).......2
NTC10K (size: dia.6*50mm, cable length1.5m)……………….4
Plastic expansion screw…………………………………………3
Screw……………………………………………………………………3
Strain-relief clamp…………………………………………………………1

 

Package per set  33cm*21cm*10cm
Package 10 sets  53cm*35cm*4cm
Net Weight  18kgs
Gross Weight  19.2kgs
Online Store Ultisolar New Energy E-Commerce on Alibaba
User's Manual  
MOQ 1 set
Lead Time <100 sets: 2 days; >100 sets: 7 days
Payment |Bank Transfer|Alipay
Contact online Skype:Chat with me||QQ: Click here to contact me by QQ 
Email: info@ultisolar.com>> ultisolar@gmail.com
MSN ultisolar@hotmail.com

SR618C6 Solar Controllers Solar Water Heater Controllers Solar Smart Controllers

Ultisolar Group:  Shop Ultisolar -|-Ultisensor.com -| -Ultisolar.cn中文版

Copyright © 2010 Shandong Isentrol Electronic Technology Co., Ltd All rights reserved.

鲁ICP备17032917号-5 Powered by Z-blog